GCS low pressure extraction switchgear

Pull-out switch cabinet

Scope of application :

It is suitable for power distribution, motor control center, capacitor compensation and electric energy conversion, distribution and control of low-voltage power distribution system in power plant, substation, petroleum, chemical industry, metallurgy, textile, high-rise building, etc.
product details
  An overview,
  GCS low-voltage draw-out switchgear is suitable for power,power distribution,motor control center,capacitor compensation and power conversion,distribution and control of low-voltage power distribution system in power plant,substation,petroleum,chemical industry,metallurgy,textile,high-rise building,etc.
  It can meet the special needs of computer interface in power use occasions such as single power plant with large capacity,low-voltage power control center and motor control center in large-scale petrochemical industry.
  With the characteristics of high breaking and connecting capacity,good dynamic and thermal stability,flexible electrical scheme,convenient combination,novel structure and high protection level,it can be used as the replacement of low-voltage draw-out switchgear.At present,GCS extraction switchgear has been widely used by power users.Meet IEC439"low-voltage complete switchgear and control equipment"GB7251"low-voltage complete switchgear"and other standard requirements.
  Ii.Environmental conditions
  1.Ambient air temperature shall not be higher than+40°c or-5°c,and the average temperature shall not be higher than+35°c within 24 hours.When the temperature exceeds this limit,the capacity shall be reduced according to the actual situation.
  2.The relative humidity of surrounding air should not exceed 50%at high temperature+40℃,and relatively large relative humidity is allowed at low temperature,such as 90%at+20℃.The influence of condensation may occur accidentally due to temperature changes should be considered.
  3.The altitude shall not exceed 2000M.
  4.The vertical inclination when installing the device shall not exceed 5%,and the whole group of cabinets shall be arranged in a relatively smooth manner.
  5.The device shall be installed in a place without violent vibration and impact and without corrosive substances.
  6.This device is suitable for transportation and storage in the following temperature range:-25℃to+55℃,and not more than+70℃in a short time(24 hours).The device shall not suffer any unrecoverable damage at these extreme temperatures and shall be able to function normally.
  7.If users have special requirements,they can negotiate with the manufacturer to solve them.
  Iii.Model and meaning
  4.Structural features
  Modular holes E=20mm are installed on the main frame.Each function room of the device is strictly separated,and its compartments are mainly divided into function unit rooms,bus rooms and cable rooms,and the functions of each unit are relatively independent.The device puts the horizontal bus in the back of the cabinet,making the cable room have outlet channels above and below.
  A.The module height of drawer layer is 160mm,divided into four size series of 1/2 unit,1 unit,2 unit and 3 unit,and rated current of unit circuit is 400A or below.
  B.The drawer changes only in height and size,and its width and depth remain unchanged;The drawer of same function unit has good interchangeability.
  C.Each cabinet of the device can be equipped with 11 1 unit drawers or 22 1/2 unit drawers.
  D.The drawer inlet and outlet lines adopt the same specification with different number of pieces according to the loop current.Generally,one piece of connector is≤200A.
  E.The transfer between 1/2 unit drawer and cable room is of type zj-2 type with back plate structure.
  F.For the connection of unit drawer and cable room,the same specification chip connector with different number of pieces is adopted according to the current,and generally one piece connector≤200A.
  G.The drawer panel is clearly marked with the position of closing and breaking test and drawing out,and the drawer is equipped with mechanical interlocking device.
  The feeder cabinet and the motor control cabinet are equipped with special cable compartment.The connection between the functional unit room and the cable compartment is realized through connecting parts or copper bars,which not only improves the use reliability of the cable,but also greatly facilitates the installation and maintenance of the cable by users.
  The number of auxiliary contacts of the functional unit of the device is 32 pairs with more than one unit.The 1/2 unit is 20 pairs.Can meet the needs of automated user and computer interface.
  It is main body with drawer,have draw out type and stationary at the same time,can mix combination,choose arbitrarily.
  The device is designed by three-phase five-wire system and three-phase four-wire system.The design department and users can easily choose PE+N or PEN mode.
  The protection grade of cabinet put oneself in another's position is IP30,IP40,can choose according to user need.
  Technical parameters
  Instructions for ordering
  1.Main circuit scheme diagram or main circuit system diagram;
  2.Control circuit electrical schematic diagram,terminal arrangement diagram;
  3.Switchgear layout plan;
  4.Color of cabinet(according to company standard if not required);
  5.List of components inside the cabinet(including name,specification,model and quantity of components);
  6.List of necessary spare parts;
  7.If you have any special requirements,please provide details.
请您留言
  • 姓名 *
  • 电话 *
  • 地址
  • 邮箱 *
  •     

Online
customer service

Online customer serviceService time:9:00-24:00

Select QQ below to communicate online now:

customer
service hotline

18569912866
7*24-hour customer service hotline

Wechat

Focus on wechat
Top